BACnet receiver LoRa – IP and/or MSTP

  • For use in LoRa private mode
  • IP and RTU RS485 / RS232 Modbus
  • Can handle up to 40 transmitters
  • Compatible with Modbus PLCs
  • Power supply 7.5 – 24 V
  • Quick and easy to install
  • Compact design

Can be used in private LoRa mode – only compatible with Enless transmitters

118 x 79 x 43mm
IP / MSTP – DHCP / BBMD interfaces
BACnet ASC profile

Reference: RX BACNET 500-312

Applications of the LoRa BACnet receiver

The Enless Wireless LoRa receiver is compatible with the BACnet protocol – the reference protocol for building automation and control. The Enless BACnet receiver complies with the specification of the B-ASC profile. It can be used both in IP and/or MSTP. DHCP as well as BBMD options can also be enabled. The Enless BACnet receiver can collect data from as many as 40 Enless LoRa transmitters.

The BACnet LoRa receiver has two user modes:

  • Object Mode: All the BACnet objects contained in the receiver are visible during discover
  • Device Mode: Only those sensor BACnet objects selected to be visible for the receiver are visible during discover

The receiver is configured using an extremely easy to access and use IP server.
The BACnet receiver has an external power supply of 7.5 to 24V.

Modbus receiver LoRa – IP and RTU RS485 / RS232 interfaces

  • For use in LoRa private mode
  • IP and RTU RS485 / RS232 Modbus
  • Can handle up to 40 transmitters
  • Compatible with Modbus PLCs
  • Power supply 7.5 – 24 V
  • Quick and easy to install
  • Compact design

For use IN LORA PRIVATE MODE – Compatible with Enless transmitters only

118 x 79 x 43mm

Reference: RX MODBUS 500-302

Applications of the LoRa Modbus receiver

This Enless Wireless LoRa receiver is compatible with PLCs with an RS485 or an RS232 Modbus RTU interface. The receiver also manages Modbus over IP communication. The Modbus receiver is used to collect data from our LoRa transmitters (Enless sensors only). The LoRa Modbus receiver can handle up to 40 transmitters. The transmitter information is stored in the receiver Modbus table. The PLC can then read the registers of the receiver to retrieve the data. It is also possible to write to the Modbus table of the receiver to re-configure already installed transmitters and add new ones. The receiver is powered externally (either directly via the PLC power supply or via a power supply unit). This product is LoRa compatible (not LoRaWAN).

Signal repeater LoRa

  • For use in LoRa private mode
  • Improves reception quality
  • High radio power
  • No limit on the number of transmitters repeated
  • No configuration required
  • Power supply 7.5 – 24 V
  • Quick and easy to install

For use IN LORA PRIVATE MODE – Compatible with Enless transmitters only

118 x 79 x 43 mm

Reference: RX REPEATER 600-301

Applications of the repeater LoRa

Thanks to its high radio power, the LoRa signal repeater enables the signal level of the transmitters to be improved in the event of poor reception, without the need for prior configuration.

This repeater has no limit on the number of transmitters to repeat. It is dedicated for use in LoRa private mode. It is powered externally (7.5 to 24 VDC). It is particularly suitable for buildings, subterranean offices or high-profile sites.